Company Profile Services News Letter Inventory Catalog Listing  
Home Contact Us Staff Login  
  Communication, Signal
& Coaxial Cables
  Data & Low
Capacitance Cables
  Fire Alarm Cables
  Instrumentation &
Tray Cable
  Thermocouple Wire
  Hook-Up Wire
  Custom Designed
Cable Worksheet
  Track Your Order
 
Search
  Aerospace Part No:
 
  Enter a complete or
partial Aerospace P/N.
  Competitor's Part No:
 
  Enter a Belden, Alpha, Berk-Tek or West Penn P/N.
 
 

Plenum Fire Alarm Cable

Non-Power Limited, Unshielded,NPLFP

  Non-Power Limited Fire Protective Cable: Non-Power Limited Fire Protective Cable: [ Non-Power Limited, Unshielded, NPLFP: 18 thru 12 AWG, Data Grade Low Capacitance (150°C) ] (Color Code Chart)
Plenum / Solid. (UL) NPLFP, 150°C.
 
 
AWG 18 (Solid) Bare Copper
Aero P/N # of Cond. Insulation Thickness (inches) Jacket Thickness (inches) Jacket O.D. (inches) Lbs / 1000'
6245K
2
.020
.010
.180
22
6345K
3
.020
.010
.192
30
6445K
4
.020
.010
.213
39
6545K
5
.020
.010
.236
48
6645K
6
.020
.010
.260
57
6645/7K
6 (stranded)
.020
.012
.288
65
           
AWG 16 (Solid) Bare Copper
Aero P/N # of Cond. Insulation Thickness (inches) Jacket Thickness (inches) Jacket O.D. (inches) Lbs / 1000'
6235K
2
.020
.010
.202
29
6335K
3
.020
.010
.216
42
6435K
4
.020
.010
.239
54
6535K
5
.020
.010
.266
67
6635K
6
.020
.012
.297
81
6635/7K
6 (stranded)
.020
.012
.315
88
           
AWG 14 (Solid) Bare Copper
Aero P/N # of Cond. Insulation Thickness (inches) Jacket Thickness (inches) Jacket O.D. (inches) Lbs / 1000'
6225K
2
.020
.010
.228
41
6325K
3
.020
.010
.244
58
6425K
4
.020
.012
.275
78
6525K
5
.020
.012
.305
96
6625K
6
.020
.012
.336
114
6625/7K
6 (stranded)
.020
.012
.363
121
           
AWG 12 (Solid) Bare Copper
Aero P/N # of Cond. Insulation Thickness (inches) Jacket Thickness (inches) Jacket O.D. (inches) Lbs / 1000'
6215K
2
.020
.010
.262
58
6315K
3
.020
.012
.284
86
6415K
4
.020
.012
.316
113
6515K
5
.020
.012
.351
140
6615K
6
.020
.015
.393
170
6615/7K
6 (stranded)
.020
.015
.438
188
           
 
Specifications

Conductor:
Solid BC

Insulation:
FEP or
Halar (ECTFE) Add "K" to P/N

Color Code:
Chart 1

Jacket:
E-CTFE (150°C)
Plenum PVC Jacket Available

Industry Approvals:
NEC Article 760-17 NPLFP

Impedance: (FEP only)
(AWG 18) 132 Ohms Nom.
(AWG 16) 116 Ohms Nom.
(AWG 14) 103 Ohms Nom.
(AWG 12) 90 Ohms Nom.

Vel. of Propagation: (FEP only)
69% Nom.

Capacitance: (FEP only)
(AWG 18) 11 pF/FT Nom.
(AWG 16) 13 pF/FT Nom.
(AWG 14) 14 pF/FT Nom.
(AWG 12) 16 pF/FT Nom.

Temperature Rating:
-40°C to +150°C

Put Ups:
1000 feet (+/- 10%)
(Available in Bulk Reels)

NON-CONDUIT