Company Profile Services News Letter Inventory Catalog Listing  
Home Contact Us Staff Login  
  Communication, Signal
& Coaxial Cables
  Data & Low
Capacitance Cables
  Fire Alarm Cables
  Instrumentation &
Tray Cable
  Thermocouple Wire
  Hook-Up Wire
  Custom Designed
Cable Worksheet
  Track Your Order
 
Search
  Aerospace Part No:
 
  Enter a complete or
partial Aerospace P/N.
  Competitor's Part No:
 
  Enter a Belden, Alpha, Berk-Tek or West Penn P/N.
 
 
  600 Volt Control Cables: [ 600V Control Cable: Foil Shield, FEP (200°C) ] (Color Code Chart)
 
  Note: Photo is for reference only.  Actual color, conductors, etc. depend on part number.
 
AWG 16 (7x24) Tinned Copper
Aero P/N # of Cond. Insulation Thickness (inches) Jacket Thickness (inches) Jacket O.D. (inches) Lbs / 1000'
1236/7
2
.010
.010
.178
31
1336/7
3
.010
.010
.190
41
1436/7
4
.010
.010
.210
52
1636/7
6
.010
.012
.259
76
1736/7
7
.010
.012
.259
87
1936/7
9
.010
.015
.342
113
1136/7
12
.010
.015
.354
145
           
AWG 14 (19x.0147") Tinned Copper
Aero P/N # of Cond. Insulation Thickness (inches) Jacket Thickness (inches) Jacket O.D. (inches) Lbs / 1000'
1226
2
.012
.015
.216
49
1326
3
.012
.015
.230
63
1426
4
.012
.015
.253
79
1626
6
.012
.015
.307
109
1726
7
.012
.015
.307
124
1926
9
.012
.015
.398
156
1126
12
.012
.015
.412
199
           
AWG 12 (19x.0185") Tinned Copper
Aero P/N # of Cond. Insulation Thickness (inches) Jacket Thickness (inches) Jacket O.D. (inches) Lbs / 1000'
1216
2
.012
.015
.250
71
1316
3
.012
.015
.266
93
1416
4
.012
.015
.294
116
1616
6
.012
.015
.358
162
1716
7
.012
.015
.358
183
1916
9
.012
.015
.466
231
1116
12
.012
.015
.482
296
           
AWG 10 (37x26) Tinned Copper
Aero P/N # of Cond. Insulation Thickness (inches) Jacket Thickness (inches) Jacket O.D. (inches) Lbs / 1000'
1206
2
.012
.015
.302
105
1306
3
.012
.015
.322
139
1406
4
.012
.015
.357
172
1606
6
.012
.015
.436
241
1706
7
.012
.015
.436
273
1906
9
.012
.015
.570
344
1106
12
.012
.015
.590
442
           
 
Specifications

Conductor:
Stranded TC

Insulation:
FEP (200°C)

Color Code:
Chart 1

Shield:
Aluminum/Mylar and Drain

Jacket:
FEP (200°C)

Impedance:
(AWG 16) 45 Ohms Nom.
(AWG 14) 43 Ohms Nom.
(AWG 12) 39 Ohms Nom.
(AWG 10) 33 Ohms Nom.

Vel. of Propagation:
69% Nom.

Capacitance:
(AWG 16) 32 pF/FT Nom.
(AWG 14) 34 pF/FT Nom.
(AWG 12) 38 pF/FT Nom.
(AWG 10) 45 pF/FT Nom.

Voltage:
Spark tested @ 5 KV for use as 600 Volts Control

Temperature Rating:
-80°C to +200°C
(Insulation & Jacket only)

Put Ups:
1000 Feet (+/- 10%)