Company Profile Services News Letter Inventory Catalog Listing  
Home Contact Us Staff Login  
  Communication, Signal
& Coaxial Cables
  Data & Low
Capacitance Cables
  Fire Alarm Cables
  Instrumentation &
Tray Cable
  Thermocouple Wire
  Hook-Up Wire
  Custom Designed
Cable Worksheet
  Track Your Order
 
Search
  Aerospace Part No:
 
  Enter a complete or
partial Aerospace P/N.
  Competitor's Part No:
 
  Enter a Belden, Alpha, Berk-Tek or West Penn P/N.
 
 
  Plenum: [ Multi-Conductors (UL) CL2P/CMP Foil & Braid: 18 & 16 AWG (200°C or 150°C) ] (Color Code Chart)
(UL) CMP. 200°C or 150°C.
  Note: Photo is for reference only.  Actual color, conductors, etc. depend on part number.
 
AWG 18 (19x30) Tinned Copper
Aero P/N # of Cond. Insulation Thickness (inches) Jacket Thickness (inches) Jacket O.D. (inches) Lbs / 1000'
1254/19R
2
.007
.015
.182
31
1354/19R
3
.007
.015
.191
46
1454/19R
4
.007
.015
.207
54
1654/19R
6
.007
.015
.243
74
1954/19R
9
.007
.015
.281
96
1154/19R
12
.007
.015
.313
121
           
AWG 16 (19x.0117") Tinned Copper
Aero P/N # of Cond. Insulation Thickness (inches) Jacket Thickness (inches) Jacket O.D. (inches) Lbs / 1000'
1234R
2
.007
.015
.200
42
1334R
3
.007
.015
.211
54
1434R
4
.007
.015
.228
63
1634R
6
.007
.015
.270
91
1934R
9
.007
.015
.313
129
1134R
12
.007
.015
.350
154
1134-15R
15
.007
.015
.389
193
1134-19R
19
.007
.015
.409
229
           
 
Specifications

Conductor:
Stranded T.C.

Insulation:
FEP

Color Code:
Chart 2

Shield:
Foil & TC Braid

Jackets Available:
FEP (200°C) or
Fluorocopolymer (150°C) Add "K" to P/N or
Plenum PVC Jacket available

Industry Approvals:
NEC Article 800-CMP

Impedance: (FEP only)
(AWG 18) 40 Ohms Nom.
(AWG 16) 35 Ohms Nom.

Vel. of Propagation: (FEP only)
69% Nom.

Capacitance: (FEP only)
(AWG 18) 38 pF/ft Nom.
(AWG 16) 42 pF/ft Nom.

Operating Temperature Range:
-80°C to +200°C (FEP/FEP)
-40°C to +150°C (FEP/E-CTFE)

Put Ups:
1000 Feet (+/- 10%)
(Available in Bulk Reels)