Company Profile Services News Letter Inventory Catalog Listing  
Home Contact Us Staff Login  
  Communication, Signal
& Coaxial Cables
  Data & Low
Capacitance Cables
  Fire Alarm Cables
  Instrumentation &
Tray Cable
  Thermocouple Wire
  Hook-Up Wire
  Custom Designed
Cable Worksheet
  Track Your Order
 
Search
  Aerospace Part No:
 
  Enter a complete or
partial Aerospace P/N.
  Competitor's Part No:
 
  Enter a Belden, Alpha, Berk-Tek or West Penn P/N.
 
 
  Plenum: [Multi-Pairs (UL) CL2P/CMP Unshielded: 24 & 22 AWG (200°C or 150°C) ] (Color Code Chart)
Stranded. (UL) CL2P or CMP. 200°C or 150°C.
  Note: Photo is for reference only.  Actual color, conductors, etc. depend on part number.
 
AWG 24 (7x32) Tinned Copper
Aero P/N # of Pair Insulation Thickness (inches) Jacket Thickness (inches) Jacket O.D. (inches) Lbs / 1000'
2271
2
.006
.010
.146
12
2371
3
.006
.010
.155
16
2471
4
.006
.010
.171
20
2571
5
.006
.010
.193
24
2671
6
.006
.010
.200
28
2771
7
.006
.010
.200
32
2871
8
.006
.010
.222
37
2971
9
.006
.010
.236
41
2071
10
.006
.010
.254
45
2171
12.5
.006
.010
.265
53
2171-15
15
.006
.015
.290
67
2171-17
17
.006
.015
.308
75
2171-18
18
.006
.015
.312
79
2171-20
20
.006
.015
.319
87
2171-25
25
.006
.015
.370
108
           
AWG 22 (7x30) Tinned Copper
Aero P/N # of Pair Insulation Thickness (inches) Jacket Thickness (inches) Jacket O.D. (inches) Lbs / 1000'
2261*
2
.006
.010
.167
16
2361*
3
.006
.010
.178
22
2461*
4
.006
.010
.196
28
2561
5
.006
.010
.222
34
2661*
6
.006
.010
.230
40
2761
7
.006
.010
.230
45
2861
8
.006
.010
.255
52
2961
9
.006
.012
.276
59
2061
10
.006
.012
.297
66
2161
12
.006
.012
.310
77
2161-15
15
.006
.012
.335
95
2161-18
18
.006
.012
.360
113
2161-20
20
.006
.012
.368
124
2161-25
25
.006
.015
.433
158
2161-27
27
.006
.015
.442
169
           
 
Specifications

Conductor:
Stranded T.C.

Insulation:
FEP or
Halar (ECTFE) Add "HL" to P/N

Color Code:
Chart 3

Jackets Available:
FEP (200°C) or
PVDF (150°C) Add "K" to P/N or
Plenum PVC Jacket available

Industry Approvals:
NEC Article 725-CL2P or
NEC Article 800-CMP
PCC FT6-C(UL) (CMP only)

Impedance: (FEP only)
(AWG 24) 100 Ohms Nom.
(AWG 22) 90 Ohms Nom.

Vel. of Propagation: (FEP only)
69% Nom.

Capacitance: (FEP only)
(AWG 24) 14 pF/ft Nom.
(AWG 22) 16 pF/ft Nom.

Operating Temperature Range:
-80°C to +200°C (FEP/FEP)
-20°C to +150°C (FEP/PVDF)
-5°C to +75°C (Halar/Aeroflex)

Put Ups:
1000 Feet (+/- 10%)
(Available on Bulk Reels)

Add to P/N:
*R = for Red Jacket CMP

Conductor Temp Rating:
150°C