Company Profile Services News Letter Inventory Catalog Listing  
Home Contact Us Staff Login  
  Communication, Signal
& Coaxial Cables
  Data & Low
Capacitance Cables
  Fire Alarm Cables
  Instrumentation &
Tray Cable
  Thermocouple Wire
  Hook-Up Wire
  Custom Designed
Cable Worksheet
  Track Your Order
 
Search
  Aerospace Part No:
 
  Enter a complete or
partial Aerospace P/N.
  Competitor's Part No:
 
  Enter a Belden, Alpha, Berk-Tek or West Penn P/N.
 
 
  Plenum: [Multi-Pairs (UL) CL2P/CMP Individual Shield: 24 thru 20 AWG (200°C or 150°C) ] (Color Code Chart)
Stranded. (UL) CL2P or CMP. 200°C or 150°C.
  Note: Photo is for reference only.  Actual color, conductors, etc. depend on part number.
 
AWG 24 (7x32) Tinned Copper
Aero P/N # of Pair. Insulation Thickness (inches) Jacket Thickness (inches) Jacket O.D. (inches) Lbs / 1000'
2272†
2
.006
.010
.172
14
2372
3
.006
.010
.184
21
2672
6
.006
.010
.248
38
2872
8
.006
.012
.328
53
2072
10
.006
.012
.328
63
2172-15
15
.006
.015
.387
94
2172-20
20
.006
.015
.434
123
2172-25
25
.006
.015
.486
151
           
AWG 22 (7X30) Tinned Copper
Aero P/N # of Pair Insulation Thickness (inches) Jacket Thickness (inches) Jacket O.D. (inches) Lbs / 1000'
2262†‡*
2
.006
.010
.196
19
2362*
3
.006
.010
.210
29
2662*
6
.006
.012
.288
56
2862
8
.006
.015
.382
78
2062
10
.006
.015
.382
94
2162-15
15
.006
.015
.444
135
2162-20
20
.006
.015
.497
176
2162-25
25
.006
.015
.558
218
2162-37
37
.006
.015
.646
315
           
AWG 20 (7X28) Tinned Copper
Aero P/N # of Pair Insulation Thickness (inches) Jacket Thickness (inches) Jacket O.D. (inches) Lbs / 1000'
2242†
2
.006
.010
.228
28
2342
3
.006
.010
.244
46
2642
6
.006
.012
.336
89
2842
8
.006
.015
.446
122
2042
10
.006
.015
.446
148
2142-15
15
.006
.015
.519
217
2142-20
20
.006
.015
.582
284
2142-25
25
.006
.015
.654
352
           
 
Specifications

Conductor:
Stranded T.C.

Insulation:
FEP or
Halar (ECTFE) Add "HL" to P/N

Color Code:
Chart 3 Except:
‡ Black/Red, White/Green

Shield:
Individual Foil Shield and Drain

† Common drain wire

Jackets Available:
FEP (200°C) or
PVDF (150°C) Add "K" to P/N or
Plenum PVC Jacket available

Industry Approvals:
NEC Article 800-CMP
PCC FT6-C(UL) (CMP only)

Impedance: (FEP only)
(AWG 24) 55 Ohms Nom.
(AWG 22) 50 Ohms Nom.
(AWG 20) 45 Ohms Nom.

Vel. of Propagation: (FEP only)
69% Nom.

Capacitance: (FEP only)
(AWG 24) 27.3 pF/ft Nom.
(AWG 22) 30.6 pF/ft Nom.
(AWG 20) 34.2 pF/ft Nom.

Operating Temperature Range:
-80°C to +200°C (FEP/FEP)
-20°C to +150°C (FEP/PVDF)
-5°C to +75°C (Halar/PVDF)

Put Ups:
1000 Feet (+/- 10%)
(Available in Bulk Reels)

Add to P/N:
*R = for Red Jacket CMP

Conductor Temp Rating:
150°C