Company Profile Services News Letter Inventory Catalog Listing  
Home Contact Us Staff Login  
  Communication, Signal
& Coaxial Cables
  Data & Low
Capacitance Cables
  Fire Alarm Cables
  Instrumentation &
Tray Cable
  Thermocouple Wire
  Hook-Up Wire
  Custom Designed
Cable Worksheet
  Track Your Order
 
Search
  Aerospace Part No:
 
  Enter a complete or
partial Aerospace P/N.
  Competitor's Part No:
 
  Enter a Belden, Alpha, Berk-Tek or West Penn P/N.
 
 
  Plenum: [Multi-Pairs (UL) CL2P/CMP Solid: 18 & 16 AWG (200°C or 150°C) ] (Color Code Chart)
Shielded & Unshielded. (UL) CL2P or CMP. 200°C or 150°C.
  Note: Photo is for reference only.  Actual color, conductors, etc. depend on part number.
 
AWG 18 (Solid) Bare Copper Shielded
Aero P/N # of Pair Insulation Thickness (inches) Jacket Thickness (inches) Jacket O.D. (inches) Lbs / 1000'
2230/1
2
.006
.010
.206
33
2430/1
4
.006
.010
.242
57
2830/1
8
.006
.010
.319
107
2030/1
10
.006
.012
.366
131
2130-25/1
25
.006
.015
.533
313
           
AWG 18 (Solid) Bare Copper Unshielded
Aero P/N # of Pair Insulation Thickness (inches) Jacket Thickness (inches) Jacket O.D. (inches) Lbs / 1000'
2231/1
2
.006
.010
.202
28
2431/1
4
.006
.010
.238
52
2631/1
6
.006
.012
.284
78
2031/1
10
.006
.012
.362
125
           
AWG 18 (Solid) Bare Copper Ind. Shielded
Aero P/N # of Pair Insulation Thickness (inches) Jacket Thickness (inches) Jacket O.D. (inches) Lbs / 1000'
2232/1†
2
.006
.010
.235
34
           
AWG 16 (Solid) Bare Copper Shielded
Aero P/N # of Pair Insulation Thickness (inches) Jacket Thickness (inches) Jacket O.D. (inches) Lbs / 1000'
2220/1
2
.007
.010
.251
51
           
AWG 16 (Solid) Bare Copper Unshielded
Aero P/N # of Pair Insulation Thickness (inches) Jacket Thickness (inches) Jacket O.D. (inches) Lbs / 1000'
2221/1
2
.007
.010
.247
43
           
 
Specifications

Conductor:
Solid B.C.

Insulation:
FEP or
Halar (ECTFE) Add "HL" to P/N

Color Code:
Chart 3

† Common drain wire

Jackets Available:
FEP (200°C) or
PVDF (150°C) Add "K" to P/N or
Plenum PVC Jacket available

Industry Approvals:
NEC Article 725-CL2P or
NEC Article 800-CMP
PCC FT6-C(UL) (CMP only)

Impedance: (FEP only)
AWG 18:
Unshielded 72 Ohms Nom.
Overall Shield 70 Ohms Nom.
Individual Shielded 37 Ohms Nom.
AWG 16:
Unshielded 70 Ohms Nom.
Overall Shield 68 Ohms Nom.

Vel. of Propagation: (FEP only)
69% Nom.

Capacitance: (FEP only)
AWG 18:
Unshielded 20 pF/ft.
Overall Shield 22 pF/ft
Individual Shield 40 pF/ft
AWG 16:
Unshielded 21 pF/ft
Overall Shield 23 pF/ft

Temperature Rating:
-80°C to +200°C (FEP/FEP)
-20°C to +150°C (FEP/PVDF)
-20°C to +150°C (Halar/PVDF)

Put Ups:
1000 Feet (+/- 10%)
(Available in Bulk Reels)