Company Profile Services News Letter Inventory Catalog Listing  
Home Contact Us Staff Login  
  Communication, Signal
& Coaxial Cables
  Data & Low
Capacitance Cables
  Fire Alarm Cables
  Instrumentation &
Tray Cable
  Thermocouple Wire
  Hook-Up Wire
  Custom Designed
Cable Worksheet
  Track Your Order
 
Search
  Aerospace Part No:
 
  Enter a complete or
partial Aerospace P/N.
  Competitor's Part No:
 
  Enter a Belden, Alpha, Berk-Tek or West Penn P/N.
 
 
  Plenum: [ Multi-Conductors 300V CL3P Shielded: 18 thru 12 AWG (200°C or 150°C) ] (Color Code Chart)
Stranded. (UL) CL3P. 200°C or 150°C.
  Note: Photo is for reference only.  Actual color, conductors, etc. depend on part number.
 
AWG 18 (7x26) Tinned Copper
Aero P/N # of Cond. Insulation Thickness (inches) Jacket Thickness (inches) Jacket O.D. (inches) Lbs / 1000'
1252CL3P
2
.010
.010
.160
24
1352CL3P
3
.010
.010
.170
31
1452CL3P
4
.010
.010
.188
39
1552CL3P
5
.010
.010
.208
46
1652CL3P
6
.010
.010
.228
54
1752CL3P
7
.010
.010
.229
61
1052CL3P
10
.010
.012
.294
90
1152CL3P
12
.010
.012
.300
100
1152-19CL3P
19
.010
.012
.369
156
1152-25CL3P
25
.010
.015
.445
203
           
AWG 16 (19X.0117") Tinned Copper
Aero P/N # of Cond. Insulation Thickness (inches) Jacket Thickness (inches) Jacket O.D. (inches) Lbs / 1000'
1232
2
.010
.010
.170
30
1332
3
.010
.010
.181
39
1432
4
.010
.010
.200
49
1632
6
.010
.012
.243
68
1932
9
.010
.012
.320
99
1032
10
.010
.012
.320
108
1132
12
.010
.012
.331
127
1132-16
16
.010
.012
.371
165
1132-20
20
.010
.015
.418
199
1132-25
25
.010
.015
.472
253
           
AWG 14 (19x.0150") Tinned Copper
Aero P/N # of Cond. Insulation Thickness (inches) Jacket Thickness (inches) Jacket O.D. (inches) Lbs / 1000'
1226CL3P
2
.012
.010
.206
46
1426CL3P
4
.012
.010
.243
75
           
AWG 12 (19x.0185") Tinned Copper
Aero P/N # of Cond. Insulation Thickness (inches) Jacket Thickness (inches) Jacket O.D. (inches) Lbs / 1000'
1216CL3P
2
.012
.012
.240
68
1416CL3P
4
.012
.012
.288
114
           
 
Specifications

Conductor:
Stranded T.C.

Insulation:
FEP

Color Code:
Chart 1

Shield:
Aluminum/Mylar

Jackets Available:
FEP (200°C) or
Fluorocopolymer (150°C) Add "K" to P/N or
Plenum PVC Jacket available

Industry Approvals:
NEC Article 725-CL3P

Impedance: (FEP only)
(AWG 18) 50 Ohms Nom.
(AWG 16) 44 Ohms Nom.
(AWG 14) 43 Ohms Nom.
(AWG 12) 39 Ohms Nom.

Vel. of Propagation: (FEP only)
69% Nom.

Capacitance: (FEP only)
(AWG 18) 30 pF/ft Nom.
(AWG 16) 33 pF/ft Nom.
(AWG 14) 34 pF/ft Nom.
(AWG 12) 38 pF/ft Nom.

Operating Temperature Range:
-80°C to +200°C (FEP/FEP)
-40°C to +150°C (FEP/E-CTFE)

Put Ups:
1000 Feet (+/- 10%)
(Available in Bulk Reels)