Company Profile Services News Letter Inventory Catalog Listing  
Home Contact Us Staff Login  
  Communication, Signal
& Coaxial Cables
  Data & Low
Capacitance Cables
  Fire Alarm Cables
  Instrumentation &
Tray Cable
  Thermocouple Wire
  Hook-Up Wire
  Custom Designed
Cable Worksheet
  Track Your Order
 
Search
  Aerospace Part No:
 
  Enter a complete or
partial Aerospace P/N.
  Competitor's Part No:
 
  Enter a Belden, Alpha, Berk-Tek or West Penn P/N.
 
 
  Plenum: [ Multi-Conductors 300V CL3P Unshielded: 18 thru 12 AWG (200°C or 150°C) ] (Color Code Chart)
Stranded. (UL) CL3P. 200°C or 150°C.
  Note: Photo is for reference only.  Actual color, conductors, etc. depend on part number.
 
AWG 18 (7x26) Tinned Copper
Aero P/N # of Cond. Insulation Thickness (inches) Jacket Thickness (inches) Jacket O.D. (inches) Lbs / 1000'
1253CL3P
2
.010
.010
.156
19
1353CL3P
3
.010
.010
.166
26
1453CL3P
4
.010
.010
.184
34
1553CL3P
5
.010
.010
.204
41
1653CL3P
6
.010
.010
.224
48
1753CL3P
7
.010
.010
.224
55
1053CL3P
10
.010
.012
.290
83
1153CL3P
12
.010
.012
.302
96
1153-
19CL3P
19
.010
.012
.364
145
1153-
25CL3P
25
.010
.015
.438
194
           
AWG 16 (19X.0117") Tinned Copper
Aero P/N # of Cond. Insulation Thickness (inches) Jacket Thickness (inches) Jacket O.D. (inches) Lbs / 1000'
1233
2
.010
.010
.166
23
1333
3
.010
.010
.177
32
1433
4
.010
.010
.196
42
1633
6
.010
.010
.239
61
1933
9
.010
.012
.316
92
1033
10
.010
.012
.316
101
1133
12
.010
.012
.327
120
1133-16
16
.010
.012
.367
157
1133-20
20
.010
.015
.414
199
1133-25
25
.010
.015
.468
255
           
AWG 14 (19x.0150") Tinned Copper
Aero P/N # of Cond. Insulation Thickness (inches) Jacket Thickness (inches) Jacket O.D. (inches) Lbs / 1000'
1225CL3P
2
.012
.010
.202
34
1425CL3P
4
.012
.010
.239
63
           
AWG 12 (19x.0185") Tinned Copper
Aero P/N # of Cond. Insulation Thickness (inches) Jacket Thickness (inches) Jacket O.D. (inches) Lbs / 1000'
1215CL3P
2
.012
.012
.236
49
1415CL3P
4
.012
.012
.284
95
           
 
Specifications

Conductor:
Stranded T.C.

Insulation:
FEP or
Halar (ECTFE) Add "HL" to P/N

Color Code:
Chart 1

Jackets Available:
FEP (200°C) or
PVDF (150°C) Add "K" to P/N or
Plenum PVC Jacket available

Industry Approvals:
NEC Article 725-CL2P or

Impedance: (FEP only)
(AWG 18) 93 Ohms Nom.
(AWG 16) 84 Ohms Nom.
(AWG 14) 83 Ohms Nom.
(AWG 12) 75 Ohms Nom.

Vel. of Propagation: (FEP only)
69% Nom.

Capacitance: (FEP only)
(AWG 18) 16 pF/ft Nom.
(AWG 16) 17 pF/ft Nom.
(AWG 14) 18 pF/ft Nom.
(AWG 12) 20 pF/ft Nom.

Operating Temperature Range:
-80°C to +200°C (FEP/FEP)
-20°C to +150°C (FEP/PVDF)
-20°C to +150°C (Halar/PVDF)

Put Ups:
1000 Feet (+/- 10%)
(Available in Bulk Reels)