Company Profile Services News Letter Inventory Catalog Listing  
Home Contact Us Staff Login  
  Communication, Signal
& Coaxial Cables
  Data & Low
Capacitance Cables
  Fire Alarm Cables
  Instrumentation &
Tray Cable
  Thermocouple Wire
  Hook-Up Wire
  Custom Designed
Cable Worksheet
  Track Your Order
 
Search
  Aerospace Part No:
 
  Enter a complete or
partial Aerospace P/N.
  Competitor's Part No:
 
  Enter a Belden, Alpha, Berk-Tek or West Penn P/N.
 
 
  Plenum: [ Multi-Conductors (UL) CL2P/CMP Foil Shield: 24 & 22 AWG (200°C or 150°C) ] (Color Code Chart)
Stranded. (UL) CL2P or CMP. 200°C, 150°C or 75°C.
  Note: Photo is for reference only.  Actual color, conductors, etc. depend on part number.
 
AWG 24 (7x32) Tinned Copper
Aero P/N # of Cond. Insulation Thickness (inches) Jacket Thickness (inches) Jacket O.D. (inches) Lbs / 1000'
1290
2
.006
.010
.096
8
1290*
2
.006
.010
.096
8
1390
3
.006
.010
.101
10
1490
4
.006
.010
.111
12
1590
5
.006
.010
.121
14
1690
6
.006
.010
.132
16
1790
7
.006
.010
.132
18
1890
8
.006
.010
.168
21
1990
9
.006
.010
.168
23
1090
10
.006
.010
.168
25
1190
12
.006
.010
.173
29
1190-15
15
.006
.010
.193
35
1190-16
16
.006
.010
.193
37
1190-20
20
.006
.010
.215
46
1190-25
25
.006
.010
.240
56
           
AWG 22 (7x30) Tinned Copper
Aero P/N # of Cond. Insulation Thickness (inches) Jacket Thickness (inches) Jacket O.D. (inches) Lbs / 1000'
1280
2
.006
.010
.108
11
1280*
2
.006
.010
.108
11
1380
3
.006
.010
.114
14
1480
4
.006
.010
.125
17
1580
5
.006
.010
.137
20
1680
6
.006
.010
.150
23
1780
7
.006
.010
.150
26
1880
8
.006
.010
.192
30
1980
9
.006
.010
.192
33
1080
10
.006
.010
.192
35
1180
12
.006
.010
.198
41
1180-15
15
.006
.010
.221
50
1180-20
20
.006
.010
.247
65
1180-25
25
.006
.012
.280
81
           
 
Specifications

Conductor:
Stranded T.C.

Insulation:
FEP

Color Code:
Chart 1

Shield:
Aluminum/Mylar

Jackets Available:
FEP (200°C)
E-CTFE (150°C) Add "K" to P/N
Aeroflex (75°C) Add "PV" to P/N

Industry Approvals:
NEC Article 725-CL2P or
NEC Article 800-CMP
C(UL) (CMP only)

Impedance: (FEP only)
(AWG 24) 55 Ohms Nom.
(AWG 22) 50 Ohms Nom.

Vel. of Propagation: (FEP only)
69% Nom.

Capacitance: (FEP only)
(AWG 24) 27 pF/ft Nom.
(AWG 22) 30 pF/ft Nom.

Operating Temperature Range:
-80°C to +200°C (FEP/FEP)
-40°C to +150°C (FEP/E-CTFE)
-5°C to +75°C (FEP/Aeroflex)

Put Ups:
1000 Feet (+/- 10%)
(Available in Bulk Reels)

Add to P/N:
*PV = for Aeroflex Jkt. CMP/75°C
*RD = for Red Jacket CMP/200°C
*KRD = for Red Jkt. CMP/150°C

Conductor Temp Rating:
150°C