AWG
20 (7x28) Tinned Copper |
|
Aero
P/N |
#
of Cond. |
Insulation
Thickness (inches) |
Jacket
Thickness (inches) |
Jacket
O.D. (inches) |
Lbs
/ 1000' |
1260 |
2 |
.006 |
.010 |
.124 |
16 |
1360 |
3 |
.006 |
.010 |
.131 |
21 |
1460 |
4 |
.006 |
.010 |
.144 |
26 |
1560 |
5 |
.006 |
.010 |
.159 |
31 |
1660 |
6 |
.006 |
.010 |
.174 |
36 |
1760 |
7 |
.006 |
.010 |
.174 |
41 |
1860 |
8 |
.006 |
.010 |
.224 |
47 |
1960 |
9 |
.006 |
.010 |
.224 |
51 |
1060 |
10 |
.006 |
.010 |
.224 |
56 |
1160 |
12 |
.006 |
.010 |
.231 |
65 |
1160-15 |
15 |
.006 |
.010 |
.259 |
80 |
1160-18 |
18 |
.006 |
.012 |
.278 |
95 |
1160-20 |
20 |
.006 |
.012 |
.293 |
105 |
1160-25 |
25 |
.006 |
.012 |
.328 |
129 |
1160-30 |
26 |
.006 |
.012 |
.349 |
153 |
|
|
|
|
|
|
AWG
18 (7x26) Tinned Copper |
|
Aero
P/N |
#
of Cond. |
Insulation
Thickness (inches) |
Jacket
Thickness (inches) |
Jacket
O.D. (inches) |
Lbs
/ 1000' |
1250 |
2 |
.007 |
.010 |
.144 |
22 |
1250/19* |
2 |
.007 |
.010 |
.149 |
23 |
1250/19RD |
2 |
.007 |
.010 |
.149 |
23 |
1350 |
3 |
.007 |
.010 |
.153 |
28 |
1450 |
4 |
.007 |
.010 |
.169 |
35 |
1450/19* |
4 |
..007 |
.010 |
.174 |
36 |
1550 |
5 |
.007 |
.010 |
.186 |
42 |
1650 |
6 |
.007 |
.010 |
.204 |
49 |
1850 |
8 |
.007 |
.010 |
.264 |
63 |
1950 |
9 |
.007 |
.010 |
.264 |
69 |
1050 |
10 |
.007 |
.010 |
.264 |
75 |
1150 |
12 |
.007 |
.010 |
.273 |
88 |
1150-15 |
15 |
.007 |
.012 |
.310 |
110 |
1150-20 |
20 |
.007 |
.012 |
.347 |
143 |
1150-25 |
25 |
.007 |
.015 |
.394 |
179 |
|
|
|
|
|
|
|
|
Specifications |
|
Conductor:
Stranded T.C.
Insulation:
FEP
Color Code:
Chart 1
Shield:
Aluminum/Mylar
Jackets Available:
FEP (200°C) or
Fluorocopolymer (150°C) Add "K"
Aeroflex (75°C) Add "PV" to P/N
Industry Approvals:
NEC Article 725-CL2P or
NEC Article 800-CMP
C(UL) (CMP only)
Impedance: (FEP only)
(AWG 20) 43 Ohms Nom.
(AWG 18) 40 Ohms Nom.
|
Vel. of Propagation: (FEP only)
69% Nom.
Capacitance: (FEP only)
(AWG 20) 34 pF/ft Nom.
(AWG 18) 38 pF/ft Nom.
Operating Temperature Range:
-80°C to +200°C (FEP/FEP)
-40°C to +150°C (FEP/E-CTFE)
-40°C to +150°C (E-CTFE/E-CTFE)
Put Ups:
1000 Feet (+/- 10%)
(Available in Bulk Reels)
Add to P/N:
*HPV = for Harlar/Aeroflex Jkt.
*RD = for Red Jacket CMP/200°C
*KRD = for Red Jkt. CMP/150°C
Conductor Temp Rating:
150°C |