  Plenum: [ Multi-Conductors (UL) CL2P/CMP Foil Shield: 20 & 18 AWG (200°C or 150°C) ] (Color Code Chart)
Stranded. (UL) CL2P or CMP. 200°C, 150°C or 75°C.
  Note: Photo is for reference only.  Actual color, conductors, etc. depend on part number.
 
AWG 20 (7x28) Tinned Copper
Aero P/N # of Cond. Insulation Thickness (inches) Jacket Thickness (inches) Jacket O.D. (inches) Lbs / 1000'
1260
2
.006
.010
.124
16
1360
3
.006
.010
.131
21
1460
4
.006
.010
.144
26
1560
5
.006
.010
.159
31
1660
6
.006
.010
.174
36
1760
7
.006
.010
.174
41
1860
8
.006
.010
.224
47
1960
9
.006
.010
.224
51
1060
10
.006
.010
.224
56
1160
12
.006
.010
.231
65
1160-15
15
.006
.010
.259
80
1160-18
18
.006
.012
.278
95
1160-20
20
.006
.012
.293
105
1160-25
25
.006
.012
.328
129
1160-30
26
.006
.012
.349
153
           
AWG 18 (7x26) Tinned Copper
Aero P/N # of Cond. Insulation Thickness (inches) Jacket Thickness (inches) Jacket O.D. (inches) Lbs / 1000'
1250
2
.007
.010
.144
22
1250/19*
2
.007
.010
.149
23
1250/19RD 2 .007 .010 .149 23
1350
3
.007
.010
.153
28
1450
4
.007
.010
.169
35
1450/19*
4
..007
.010
.174
36
1550
5
.007
.010
.186
42
1650
6
.007
.010
.204
49
1850
8
.007
.010
.264
63
1950
9
.007
.010
.264
69
1050
10
.007
.010
.264
75
1150
12
.007
.010
.273
88
1150-15
15
.007
.012
.310
110
1150-20
20
.007
.012
.347
143
1150-25
25
.007
.015
.394
179
           
 
Specifications

Conductor:
Stranded T.C.

Insulation:
FEP

Color Code:
Chart 1

Shield:
Aluminum/Mylar

Jackets Available:
FEP (200°C) or
Fluorocopolymer (150°C) Add "K"
Aeroflex (75°C) Add "PV" to P/N

Industry Approvals:
NEC Article 725-CL2P or
NEC Article 800-CMP
C(UL) (CMP only)

Impedance: (FEP only)
(AWG 20) 43 Ohms Nom.
(AWG 18) 40 Ohms Nom.

Vel. of Propagation: (FEP only)
69% Nom.

Capacitance: (FEP only)
(AWG 20) 34 pF/ft Nom.
(AWG 18) 38 pF/ft Nom.

Operating Temperature Range:
-80°C to +200°C (FEP/FEP)
-40°C to +150°C (FEP/E-CTFE)
-40°C to +150°C (E-CTFE/E-CTFE)

Put Ups:
1000 Feet (+/- 10%)
(Available in Bulk Reels)

Add to P/N:
*HPV = for Harlar/Aeroflex Jkt.
*RD = for Red Jacket CMP/200°C
*KRD = for Red Jkt. CMP/150°C

Conductor Temp Rating:
150°C